Zigbee2mqtt reset coordinator

Fox Business Outlook: Costco using some of its savings from GOP tax reform bill to raise their minimum wage to $14 an hour. 

I have a Sonoff 3. If it outputs failure it could mean your user does not have access to the port. full. 15. Make sure zigbee2mqtt is stopped, and disable start at system startup. 0) has, according to the changelog, the possibility to upgrade from z-stack 1. We have now received feedback from our lovely Customers about using 6 items with one Home Assistant. the tool. advanced: # Optional: state caching, MQTT message payload will contain all attributes, not only changed ones. dreadino July 13, 2022, 7:53am 3. Devices always showed the connection. HTH. No branches or pull requests. Zigbee USB adapter). After resetting the bulb will automatically connect. Bug Report What The router flashed dongle to join the zigbee2mqtt device list, and work as a router. Demo: video. setup a Raspberry Pi Zero with the adapter connected while running Zigbee2MQTT on a different system. I will then change my 2652 coordinator in the house from ZHA to ZigBee2MQTT (this supports the Aqara switches better) and will operate in the garage the Lan Coordinator EFR32MG21 with ZHA (in the garage there are only temperature sensors and a socket). 4 firmware. LED Strip: You get kind of screwed here, Touchlink couldn't find it, BLE couldn't find it, and the Hue couldn't discover it. Step 2 - Allow join on your coordinator and simple press (not a long press) the reset button. . thanks for the quick info. Shut down system and switch out the ezsp adapter for the znp. This will allow put the remote in pairing mode and pair to Zigbee2MQTT. Enable the MQTT integration. 5. Topic. x) in docker containers. # Availability payload. This is done by clicking either of the two rockers quickly Jun 5, 2024 · Here’s how I would choose a coordinator based on the integration: Best Zigbee USB Coordinator for ZHA Sonoff ZBDongle-E | SMLight SLZB-07 Best Zigbee LAN/PoE Coordinator for ZHA SMLight SLZB-06M | ZigStar UZG-01. This is known to happen devices from: Centralite, General Electric, Iris, Ledvance, Legrand, OSRAM, Sylvania, SmartThings, Securifi. db and coordinator_backup. Click on Devices Edit of the first task and select Communication - Serial Server from the dropdown list. 01. Router 2: 21. In the top right of the screen click on the 3 dot menu and select ‘Repositories’. d. Feb 25, 2020 · Hi, I just set up a group of 6 Hue light bulbs (model LCT001 and model LWB004) with a Hue remote dimmer (model RWL021 - 324131092621) together with zigbee2mqtt. What happened I had a router (OSRAM Smart+ plug) failure today and the devices that were connected are offline. Every now and then I discover Zigbee2MQTT exiting operation without restart Oct 21, 2022 · Copy the zigbee2mqtt and paste the folder and rename it to zigbee2mqtt2. Hold the I/On and 0/Off button pressed simultaneously for 10 to 12 seconds until…. wait 2sec. When paired, the light blinks green. No errors in logs, receiving sensors data, but unable to send commands to switches or plugs. Start with bulb on, then off For flashing procedure follow DigiBlurs guide up until step 6. Change your configuration. After this the device will automatically join. yaml, database. Zigbee2MQTT is configured using YAML based configuration. Click the ‘Add-On Store’ button in the bottom right of the screen. # Options. 07 and my system Debian11 on the Hyper-V host. 0 USB Dongle Plus. 4 days ago · open in new window. 4 participants. Milestone. port: tcp://192. Higher timeout for active devices results in less pinging so less stress on the coordinator. Click + Add Integration. mfacer (Matt) February 1, 2022, 2:24pm 3. Make sure that it's flashing a 7. A couple of new HA integrations are used with the multiprotocol Add-On to provide an auto-discovery of a “SkyConnect Multi-PAN” ZHA integration. # Has to be true when integrating via Home Assistant (default: true) cache_state: true # Optional: persist cached state, only used when cache_state: true (default: true) cache_state_persistent: true # Optional: send cached state on startup, only used when cache_state_persistent: true Nov 14, 2023 · I flashed the example onto my STM32WB55 Nucleo and the board can connect with the STM32WB55 Nucleo USB stick, but not with my ZigBee2MQTT setup. # OTA updates. Integrate your SONOFF ZBDongle-E via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. Actions are only sent for input 1 of the device. Plug in your adapter and put it in BSL mode, consult your adapters manual on how to put it in BSL mode. Reflash the firmware on your stick Zigbee2MQTT doesnt even show the sensor values. Zigbee2MQTT:warn 2019-11-09T13:04:03: Set ` permit_join ` to ` false ` once you joined all devices. test -w /dev/ttyACM0 && echo success || echo failure ). Click the Device name. Edit: I had to repair a couple times, then everything started working. Zigbee to MQTT bridge, get rid of your proprietary Zigbee bridges. yaml to specify the channel you want; OR. Last Updated: Docker Configuration. In the first step, I installed the add-on a second time (with / at the end of the URL). TIP. 3. yaml set homeassistant: true. Bring the dimmer switch next to the bulb, as close as possible. Then rename in the config of the Edge AddOn the data_path to zigbee2mqtt2. Dec 16, 2021 · I installed telnet into the container to do some further analysis: apk --update --no-cache add busybox-extras. Zigbee sensor not linked to closest router. 4. My zigbee map ( zigbee component) already worked perfectly. The light will be static red when the reset is complete. Best Zigbee USB Coordinator for Zigbee2MQTT Sonoff ZBDongle-E | SMLight SLZB-07p7 Best Zigbee LAN/PoE Coordinator for Zigbee2MQTT Jan 6, 2024 · But I’m having trouble getting the different Zigbee2MQTT instances to work. With zigbee2mqtt+ha works rather well, may be delay 1 second to light up (perhaps moving orientation works better) and the 15 seconds delay i would prefer 10 Hue dimmer switch. To reset Child Lock without Z2M, quickly press the physical button 4 times # Pairing Jul 2, 2023 · Verify that the user you run Zigbee2MQTT as has write access to the port. Copy the IEEE Address and save it. Navigate to the Configuration tab and create a new user with any credentials you want to. It is now in pairing mode. I changed the serial adapter settings to the following - which is the IP Address of my new Pi running ser2net. yaml next to configuration. 16. Click the Bind tab in the device’s menu. . The configuration. 11:20108. 0. Then press and hold the setup button again until the light starts blinking orange. Enabled: checked. The light on the CC debugger should now turn GREEN. And it’s starts and works fine for half an hour. May 6, 2024 · zigbee2mqtt gateway is a standalone nodejs application that connects a zigbee network to MQTT. Fill the old coordinator ieee address into "Secondary Address" -> "IEEE 802. Start with bulb on, then off To initiate setup mode, press and hold the setup button on the rear of the device for +- 5 seconds until the setup light blinks red. If the light on the CC debugger is RED press set reset button on the CC debugger. Expand the Zigbee info dropdown. How to use device type specific Dec 22, 2022 · For ZHA or Zigbee2mqtt to talk to the Zigbee stack, it has to connect to it using a tcp socket://<ipaddress>:9999 and from what I can tell, this runs EZSP over this socket. Dec 11, 2019 · When using the default Zigbee2mqtt CC2531 coordinator firmware + 2 CC2531 routers your device limit will be: Coordinator: 15 - 2 routers = 13. Nov 2, 2022 · Hi All, I just moved my HA machine to a different location in the house and a couple of devices are giving me some trouble so I thought I would delete every device from the Z2MQTT dashboard, factory reset each device then rebuild the network. I have started with a fresh install. Set in the zigbee2mqtt2 config homeassistant: false; Then change in the normal AddOn the serial path of the coordinator und delete the database file and set homeassistant: false Step 1 - Reset the device, press the reset button for 8 seconds (it's the hole on the device). Still struggling? just get in touch with us via Telegram!! can't get any serial debug messages¶ Your serial monitor need to release Jan 15, 2023 · @Tinkerer,. Navigate to Settings > Add-ons > Add-on Store and search for MQTT. Router 1: 21. # Exposes # Battery low (binary) Feb 4, 2020 · @CodeFinder2 zigbee2mqtt will only reset the CC1352P-2 when the configuration has changed. c. Z2M config by default, port: tcp://192. Once the bulb is found you can reset. There is a hidden reset button under the cover, in case of repairing or other issues press it for 5 seconds. The bulb flashes a couple of times. There are network connected coordinators designed to work with ZHA and Zigbee2MQTT. x firmware, if not use Custom URL with a 7. In your Zigbee2MQTT configuration. To factory reset/pair: Texas Instruments CC2531: press the S2 button for 5 seconds. I currently have 3 CC2531 routers, so in theory I could expand to 75 zigbee devices. 22. The behavior is similar to method 1. You will notice some clusters of the device are already bound to the coordinator. May 27, 2023 · What happened? Dear All, I am running Zigbee2MQTT in a docker with Sonoff zStack3x0 Coordinator revision 20210708 radio. repeat above steps 2 further times. andy. I run mqtt and zigbee2mqtt (koenkk/zigbee2mqtt:latest-dev 1. bin ) and koenckk (CC1352P2_CC2652P_launchpad_coordinator_20230507. To pair - long-press the main big rotating button. With that out of the way, here’s how to add ZHA to an existing Zigbee2MQTT setup on the same coordinator: Navigate to Settings > Devices & Services. b. How to reproduce it (minimal and precise) Flash one sonoff dongle with firmware CC1352P2_CC2652P_launchpad_coordinator_20220219 Set it up with zigbee2mqtt add some zigbee devices on it (so far, everything works) (now the problem) If Zigbee2MQTT fails to start with a CC1352P-2 with Error: SRSP - SYS - version after 6000ms, you most probably have connected your device to a system that requires pressing the reset button (the one next to the USB connector) momentarily/shortly after connecting the USB cable. It seems my range is pretty low though. So I also updated the firmware of my coordinator and of my routers. And than the zigbee network offline again. I am running windows10/VirtaualBox/Home Assistant. auth_token: '!secret. 1. The hardware is a Lenovo M900 with a Sonoff Zigbee 3. yaml with content auth_token: super-secret-token. The easiest way to integrate Zigbee2MQTT with Home Assistant is by using MQTT discovery. Philips Hue bulbs as they cannot be factory reset by turning them on/off 5 times. Method 1: Press all four buttons for 4 seconds. yaml, set the adapter to ember. Zigbee2mqtt starts but there are no devices. Flash the latest firmware on your adapter: SkyConnect. Way better than my ZHA network Apr 5, 2020 · Remove the battery, like 15 minutes (probably it work with 2 o 3 minutes but i did it that way). bulbs are still powered = zigbee network). Development. Nov 2, 2020 · EDIT2: turns out the database was backed up, not sure if this happened upon changing the coordinator or an upgrade to 117 as I did both this morning. Select Mosquitto broker and click Install. Start with bulb on, then off Factory reset the light bulb (video open in new window). Help to make the docu better and edit this page on Github . TCP Port: a number between 1000 and 9999 "1775". Start zigbee2mqtt; If both LED's will turn off during starting zigbee2mqtt we don't have the correct version or some bad settings! Check your configuration. The Dongle has 5 days ago · Factory reset the light bulb (video open in new window). Start with bulb on, then off Feb 1, 2022 · So if you add new routers to the network, you have to re-pair the aqara sensors in-situ to take advantage of a new better possible route. Select your adapter, go to "MAC address". db to my new zigbee2mqtt installation (in my case Zigbee2mqtt running in a lxc container on Proxmox) This does not seem to work. An image for illustration: Now, to reset the energy meter, or Summation Delivered as its named in ZHA do the following: Apr 6, 2023 · Open up your Home Assistant instance. Apr 11, 2024 · I went back to the Home Assistant Zigbee2MQTT add-on and went to the configuration section. g. Bulbs: Remove the bulbs, place a lamp near your zigbee coordinator, plug in the bulb and power it. Instructions on how to install it can be found here. Jun 19, 2021 · The answer is simple - it's a TWO stage process: Step 1 - Set the channel you want. By pressing the reset button on the CC2531 the green LED should go off. Configuration. Zigbee2MQTT supports a variety of adapters with different kind of connections like USB, GPIO or remote via WIFI or Ethernet. For that reason, there is also a backup of the coordinator in the file coordinator_backup. The Z2M admin flow is a node-red flow for managing the zigbee2mqtt gateway and connected devices. Mar 22, 2023 · Hi I am new to Home Assistant and the forum and have been asking this question in the wrong place. Every Zigbee device you have added to Zigbee2MQTT, is paired with a single coordinator. With the new firmware flashed, we can configure Zigbee2MQTT to start using the new ember driver. Zigbee2MQTT is configured using YAML open in new window based configuration. I think by changing network_key to network_key_string caused a (non-desired) change in the network key being used, therefore zigbee2mqtt will reset the CC1352P-2. More detailed information about this can be found here open in new Pairing. # Change clickmode. Jul 3, 2022 · The configuration file is nothing without the coordinator. Nov 20, 2023 · I have two SNZB-06P, one with zigbee2mqtt+ha and other in other home with Amazon Alexa Studio (with zigbee hub), both are in the bath (in their respective homes) to swith on/off the light. 36. # Reset energy. Also replace 20108 with the port you configured while flashing the Gateway (in step 6 from previous point). If you haven’t already, you will need to update to Zigbee2MQTT version 1. This is especially handy for e. json, all from the config/zigbee2mqtt/ folder. The light blinks green in pairing mode. This can be tested by executing: test -w [PORT] && echo success || echo failure ( e. That would mean, if I don’t misunderstand the PR , we would be able to upgrade from an old coordinator to a new one without the need to re-pair the devices. Hopefully this is the correct place. Debug info Zigbee2MQTT version: 1. Anyway, full agreement that CC2652 is the way to go, you night be tempted to go with something like the Nortek HUSBZB-1 that has ZigBee and Z-Wave in one stick but I would advice against that as both radios are outdated and you will be better served by a CC2652 ZigBee coordinator and a Gen7 Z-Wave stick. Pairing. Press and hold the reset button on the device for +- 5 seconds (until the blue light starts blinking). 4. yaml has to be writeable for Zigbee2MQTT process because it can get updated - e. Then I will probably do it differently. Set network_key: GENERATE to let Zigbee2MQTT generate a new random key on the first start. If you are wondering, why I am trying this, It's because, my ZigBee2Mqtt is inside a virtual machine, that I would like to be able to move between hosts. Apr 16, 2023 · In my case, was working fine as received, but with current zigstar firmware ( ZigStarGW_v0. We will use ser2net for this which allows to connect to a serial port over TCP. When endpoint 1 is bound to a light or a group of lights, the behavior is as follows (for a triple band model): Besides serving as a coordinator some adapters can also be used as a Zigbee router (check if there is a router firmware by clicking on your adapter). This device supports OTA updates, for more information see OTA updates. In file editor: download configuration. This allows Zigbee2MQTT to automatically add devices to Home Assistant. But when I do a telnet odroid 1883 then it hangs and cannot connect. Now try starting Zigbee2MQTT again. Starting Zigbee2MQTT with Ember driver. Following the Zigbee2MQTT docs, you can skip to step 3. if you change the settings in the frontend. yaml accordingly, replace 192. Once you see something similar to below in the log your device is paired. As the device is sleeping by default, you need to wake it up after sending the bind/unbind command by pressing the reset button once. More detailed information about this can be found here open in new 5 days ago · Factory reset the switch by pressing and holding left and right rocker for 10 seconds. You can take a look in the console output or in the z2m-logfile to see, if the link quality goes up when the TRADFRI outlet is in place. To reset it into pairing mode power-cycle it three times as follows: power on. More detailed information about this can be found here open in new Factory reset the light bulb ( video ). power on and wait for it to join your network. yaml to NOT include rtscts: true in the advanced section. As you know this means re-pairing all the devices. Copying the entire set of files does not seem to work either. However, this simple measure might yield to a network with weird behavior, if messages to an end device reach their target, but responses (or messages) from that end device do not reliably reach the coordinator: Introducing a router ( read more about 4 days ago · Factory reset the light bulb ( video ). Home Assistant Zigbee2MQTT Add-On Configuration. Zigbee2MQTT:info 2019-11-09T13:04:03: Connecting to MQTT server at mqtt://localhost Zigbee2MQTT:info 2019-11-09T13:04:03: Connected to MQTT server In order to use Zigbee2MQTT we need the following hardware: A Zigbee Adapter which is the interface between the Computer (or Server) where you run Zigbee2MQTT and the Zigbee radio communication. If not use CC debugger user guide. yml gets updated with the new key. For input 2 no actions will be sent (so a double rocker is not supported). Connect CC debugger --> Downloader cable CC2531 --> CC2531 USB sniffer. Power-supply the bulb. The device will flash green and red alternatively after which it will reconnect to the network. In this way you can e. json. 168. Dec 8, 2020 · I assumed it was the former but when it prompted are you sure, I got scared! 1 Like. 1x CC1352P-2 costs $50 (100+ devices) 1x CC2531 costs $3 (~30 devices) 4x CC2531 costs $12 (~120 devices) However, I'm not yet familar with all topics over MQTT and if the HA integration would support multiple zigbee2mqtt instances communicating to it. Any more than 15 feet I get very poor connections. # Reset lock. When endpoint 1 is bound to a light or a group of lights, the behavior is as follows (for a single band model): Feb 2, 2021 · The newest version of Zigbee2MQTT (1. Just enable adding devices in zigbee2mqtt and hold the button on the sensor. I'm using the edge addon right now, but 5 of my 14 This is known to happen devices from: Centralite, General Electric, Iris, Ledvance, Legrand, OSRAM, Sylvania, SmartThings, Securifi. Aug 30, 2023 · I have found a temporary way for this to work by running one coordinator with ZigBee2Mqtt, and the other coordinator connecting to the another instance of the edge version of ZigBee2Mqtt. 5 Likes. Migration from an older Zigbee Coordinator adapter to a new Zigbee Coordinator adapter (with later firmware) a is a nice feature that both ZHA and Zigbee2MQTT have but if you are having problems with your Zigbee network after migration then it is generally recommended to cut your losses instead or troubleshooting and so just reset the new This how-to explains how to run Zigbee2MQTT with an adapter on a remote location. In case there are issues when pairing, see the FAQ Dec 22, 2021 · After that, using zigpy-znp, I reset the adpater conf, and restart Zigbee2MQTT. In the zigbee2mqtt container I can do a nslookup odroid and it resolves the correct ip address 192. power off. To specify the auth_token in a different file set e. For that, you just need to run a separate instance of Zigbee2MQTT for each coordinator. Troobleshooting: The Legrand bridge shall be power off if Feb 2, 2020 · a TRADFRI control outlet so whith permanent power and when I request the DB it is seen as a router. 0 and when I originally set it up a couple of months ago the network was rock solid and really fast. 10. With one of the two Hue Dimmer switches it is possible to put the bulbs into a factory reset. Zigbee2MQTT allows to factory reset devices through Touchlink. yaml file. 30:6638 Feb 8, 2023 · After that, I can only restart the zigbee network by going to Tools/zigbee restart on the SMLIGHT SLZB-06 website and then restarting zigbee2mqtt addon on HA. Jul 8, 2022 · Tinkerer (aka DubhAd on GitHub) July 8, 2022, 7:19pm 2. I’m pretty sure it just runs a reset on your co-ordinator (eg restart it): zigbee2mqtt. shilton December 28, 2020, 8:34pm 2. After that, install battery and reset device, paired at first attempt, the other 2 swtiches paired at first 2 Likes. Configure. No node-red nodes are required to use And with 4 USB ports in the Pi, I can scale up to 4 networks (later). I´ve activated pairing as a coordinator in the web UI and started the application on my Nucleo board. Zigbee2MQTT:info 2019-11-09T13:04:03: Zigbee: allowing new devices to join. Perfect than this device should automatically route those messages AFAIK. Think I’ll open a github issue as this isn’t expected behaviour afaik. Afterwards open the web interface again. Go to Z2M > TouchLink > Scan. Stop zigbee2mqtt (either by stopping the service or stopping the docker container) First check if the device page ( Supported devices, click on the model number) contains instructions on how to pair your device. Jun 7, 2023 · Select your controlling the device (the source of the bind) In my case Moes Smart Button ERS-10TZBVB-AA. db. To reset Sum of consumed energy, use the Dev console and execute: Endpoint: 1 Cluster: 0x00 Command: 0 Payload: (don't change this) Next time the plug gets polled, Sum of consumed energy will start from zero again. Zigbee2MQTT enables the user to increase the transmission power for some coordinator models. Reduce Wi-Fi interference by changing the Zigbee channel. A possible solution is to connect the device directly to the central coordinator by pushing the reset button while being physically close to it. Start with bulb on, then off The pinging can be heavy on the coordinator, especially if you are using a CC2530 or CC2531 adapter. Turn on the Start on boot and Watchdog toggles. What works is to use (very) short “on’s” and a little bit longer “off’s”, where you kill the light as soon as the bulb shows signs of turning on. But you can flash the SLZB-06 with router firmware As the device is sleeping by default, you need to wake it up after sending the bind/unbind command by pressing the reset button once. Your database is backup up in the file database. The CC2531 has 2 buttons on it, the reset button is the one which is closest to the USB port. I recently decided to make my network more secure and add a network key. To factory reset a device through Touchlink bring the device close (< 10 cm) to your Zigbee Coordinator (e. To test assign write access by executing: sudo Yes, you can. Everyhing is at the latest releases. # Texas Instruments LAUNCHXL-CC26X2R1 coordinator only: verify that you have the correct revision Feb 29, 2024 · I cover the process extensively, including firmware updates for the Zigbee radio and ESP32 board. 11. yaml auth_token', create a file called secret. Oct 21, 2022 · According to docs I simply need to copy the database. May 9, 2024 · If everything went correctly, after reconnecting to your coordinator, you will see the new firmware version listed as 7. 178. After powercycle works some hours more and stops again. The docker containers for Zigbee2MQTT do not wrk well with mdns, so for coordinators WITH Ethernet use the ip address of the coordinator here. 81. Click (X) Devices. Connect BOTH the CC2531 USB sniffer and the CC debugger to your PC using USB. All say unknown except LQI. Make sure the thermostat has a good signal from ZigBee coordinator. If running the add-ons, that is the way. While pairing, keep the bulb close to the coordinator (adapter). 2 to 3. izakstern April 17, 2020, 2:17pm 17. More detailed information about this can be found here open in new MQTT discovery. My plan is to have 4 LAN coordinators (CC2652) distributed in the house with Zigbee2MQTT and one LAN coordinator (EFR32) with ZHA for the outdoor devices. Factory reset the light bulb ( video ). I got this output but no successful connection: [M4 APPLICATION] APP_ZIGBEE_Init If you are running Home Assistant OS or a Supervised Home Assistant instance the easiest way to install Zigbee2MQTT is via the addon. You can set up as many SLZB-06 coordinators as you want with one Home Assistant. Thanks to danielull and frenck for their help. Changing the network_key requires repairing of all devices. io. Unfortunately they are out of stock. 6. My HA version 2023. For Source endpoint, select the output endpoint of clusters, usually 1. Sep 13, 2023 · Getting Zigbee2MQTT installed and talking to the SkyConnect. 2. For a third you could use a pi zero w2 or something like that. hex) hangs every some hours with Zigbee2MQTT. The reset button is the small hole in the side of the device - you will need a pin or needle to push into the small hole. Mar 8, 2024 · Navigate to Settings > Devices & Services > Zigbee Home Automation. Start with bulb on, then off Factory reset the light bulb ( video ). If no instructions are available, the device can probably be paired by factory resetting it. I had another backup anyways… phew. 4 MAC address" (first 0x can be skipped) Press "Write". No need to pass any devices through to Zigbee2MQTT docker container setups. If you have issues changing the click_mode with Zigbee2MQTT you can switch between click mode physically. 2. To achieve the best possible integration (including MQTT discovery): In your Zigbee2MQTT configuration. 2-dev commit: 897f5a9 Adapter hardware: ConBee2/RaspBee2 Adapter firmware version: 26660 Jan 21, 2019 · Coordinator needs to be started with zigbee2mqtt once, outside the network range When this is not done ('normally'), the coordinator will use a different pan_id because the old pan_id is already in use by the old network (e. Search for Zigbee Home Automation and select it. 13 with the IP or hostname of your system where the adapter is connected to. Name: ZIGBEE2MQTT. Now edit the Zigbee2MQTT configuration. In short, the new Sonoff stick seems to Pressing the yellow reconfigure button in the About tab will reset the bindings of the coordinator, but it will not unbind any groups - they have to be unbound explicitly. No milestone. Could be because my coordinator is inside my open network rack, probably a lot of EMI. Method 2: Use a needle or paperclip to press the reset button on the back for 10 seconds. 21. When the light turns green, release the buttons. Head back to our Home Assistant Settings page and select ‘Add-ons’. serial : adapter: ember. Change it in the zigbee2mqtt GUI by going to Settings > Advanced > ZigBee channel. Those are going to be much simpler to get working than battling with some device that needs custom firmware flashed to it. It has a zigbee coordinator which forms the zigbee network and lets you control and view zigbee devices using MQTT. By default the published availability payload is in legacy mode (online/offline). SONOFF Dongle-E, ZB-GW04, SMLIGHT SLZB07. Step 2 - Apply the change. At first boot it will automatically be in pairing mode and join your network. The data directory and the configuration. The file have to be located in the data directory within your installation. Device limit of 55 devices. Fill in the form as following: a. uo vb cv gz kx jk yc wu mp yv